Categories of Duty of various types of building and recommended performance levels relating to crowd pressure as defined by BS5234 are given below:

 


Light duty (LD)
Adjacent space only accessible to persons with high incentive to
exercise care; small chance of accident occurring or of misuse
Domestic accommodation
Medium duty (MD)
Adjacent space moderately used, primarily by persons with some incentive to exercise care; some chance of accident occurring or of misuse Office accommodation
Heavy duty (HD) Adjacent space frequently used by the public and others with little incentive to exercise care; chances of accident occurring Public circulation areas, industrial areas, schools, universities
Severe duty (MD) Adjacent space intensively used, by the public and others with little incentive to care; prone to vandalism and abnormally rough use
Major circulation areas, heavy industrial areas

 

BS 5234 – Crowd pressure

“The crowd pressure test is an additional test suitable for HD and SD grade partitions. The recommended performance levels are given in Table 5”.

 

Table 5

Recommended performance levels Principal criteria. No collapse or dangerous damage

0.75 KN/m Medium duty

1.50 KN/m Heavy duty

3.0 KN/m Severe duty

Refer to BS 6399 part 1 ‘Code of practice for dead and imposed loads’